产品展厅收藏该商铺

您好 登录 注册

当前位置:
上海爱泽工业设备有限公司>技术文章>ABB 氧化锆分析仪 AZ25 AZ20两者的区别

技术文章

ABB 氧化锆分析仪 AZ25 AZ20两者的区别

阅读:1589          发布时间:2017-10-20

The Endura AZ20 is the latest in a long line of high-quality, combustion gas analyzers from ABB.

The sensor, based on a zirconium oxide cell, is mounted at the tip of the probe that is inserted in the flue duct. The resulting direct, in situ measurement provides accurate and rapid oxygen reading for combustion ** / optimization and emissions monitoring purposes.

Endura AZ20 has been designed for extended periods of maintenance-free operation. The modular design with reduced component count improves the reliability and robustness of the system and simplifies breakdown repair if it occurs.

Kits containing all the parts needed to complete on-site repairs are available from ABB, ensuring that service personnel can effect repairs quickly and efficiently at minimum cost. The Endura AZ20probe has retained an easy-access cell arrangement, similar to the proven ZFG2 probe. This ensures cell replacement can be carried

out on-site using readily available, basic hand tools, even after long periods of high temperature operation.

The Endura AZ20 oxygen probe measures oxygen*** in flue gas using an in situ 'wet analysis' method. The 'wet analysis' method avoids measurement error (typically20% of reading higher than the actual value) that is ***by a sampling system using the 'dry analysis' method.

For customers with an existing installed ZFG2 probe with a ZMT or ZDT transmitter, a 55 V heater version of the Endura AZ20probe (the Endura AZ20 / ZFG2 replacement probe) is available.

System equipment comprises a (flue-mounted) Endura AZ20probe *** by an integral or remote transmitter. During operation, a zirconia cell within the probe is held at a constant temperature of 700°C (1292 °F) by a probe heater

thermocouple assembly. If the heater ***circuitry or software fails (unsafe), the probe heater power supply is switched off, ensuring the system fails 'safe' and protects the heater from an over-temp failure.

An output generated at the zirconia cell is processed in the transmitter giving a locally displayed O2 reading and a 4 to 20mA retransmission signal over any range between 0 % and 100% O2.

Optional automatic calibration (AutoCal*) enables automatic,semi-automatic or manual calibration to be performed using a probe-mounted gas*** manifold mounted within the probehead. Calibration sequencing is software-*** from thetransmitter.

Optional restrictors (where fitted*) in the probe head *** thetest gas and reference air flow without the need for flowmeters.The probe requires only preset test gas and reference airpressures of 1 bar (15 psi) to maintain a constant flow of 2.2 l /min (4.662 scfh). This flow is not affected by changes in themeasured gas pressure of ± 0.35 bar (5 psi). 

 

The Endura AZ25 combustion oxygen analyzer is the latest ina long line of high-quality, combustion gas analyzers fromABB. The AZ25 is designed to measure oxygen **** high temperature furnace atmospheres.

The sensor, based on a zirconium oxide cell, is mounted at thetip of the probe that is inserted directly into the furnace. Theresulting direct, in-situ measurement provides an accurate andrapid oxygen reading, for combustion optimizationand process quality ** purposes.

The in-situ technique provides a true oxygen measurementinside the process. It eliminates 'equilibrium shift' that iscommon to systems in which gas samples are extracted andcooled before measurement.

Reference air (500 to 1000 ml/min [1 to 2 ft3/hr]) is required foraccurate operation and can be supplied from an ABBmains-powered pump unit or a flow regulator unit.

Unique integrated automatic calibration

The Endura AZ25 automatic calibration system eliminates theneed for the expensive ancillary ***forautomatic calibration on ***l flue gas oxygen analyzersystems. ABB’s fully integrated, automatic calibration feature

** the test gas sequence and detects test gasavailability, eliminating incorrect calibrations due to loss of testgas. Integrated automatic calibration secures the oxygenmeasurement, providing complete confidence in the analyzer's

performance.

Long-term operation without technician ** minimizesoperating costs, total cost-of-ownership and optimizes systemaccuracy. A significant proportion of service visits to ananalyzer result in 'no fault found'. Endura AZ25's high-quality

manufacture, advanced diagnostics and automatic calibrationis targeted at reducing this wasted effort and cost.

Dependable

— measurement of O2 in a wide variety of processes

— virtually instantaneous response

— resistance to sulphurous reducing atmospheres

Versatile

— 600 to 1250 mm (2 to 4 ft) lengths

— choice of protective sheath materials

— integral thermocouple for automatic temperature

compensation

— high temperature operation up to 1400 °C (2552 °F)

Low cost-of-ownership

— in situ measurement

— no sampling system required

— automatic calibration functionality as standard

— optional automatic calibration hardware

Applications

— Furnace atmosphere monitoring:

— Annealing furnace

— Sintering of metals

— Ferrite sintering

— Whiteheart malleablizing

— Combustion measurement :

—Soaking pits

—Process heaters

—Fluidized bed boilers

—High temperature incinerators

— All other combustion processes where the flue gastemperature is in excess of 600 °C (1112 °F)

 

Aluminous porcelain

level sheath material suitable for applications withtemperatures up to 1250 °C (2282 °F) – limited resistant tocorrosive chemicals and mechanical and thermal stress.

Recrystallized alumina

Suitable for applications with temperatures up to 1400 °C(2552 °F) resistant to corrosive chemicals and more severemechanical and thermal stress are present.

Incoloy 800

Suitable for applications with temperatures up to 850 °C

(1562 °F) when mounted horizontally and up to 1000 °C

(1832 °F) when mounted vertically.

Offering limited resistance to corrosive chemicals and resistantmechanical and thermal stress.

爱泽工业(IZE_INDUSTRIES)销售型号示例:

ABB 氧化锆分析仪AZ25/.1.1.2.1.1.5.3.1.2.0.0.0.0 /STD

ABB 氧化锆分析仪AZ25/.1.1.2.1.1.5.1.1.1.1.0.0.0.0

ABB 氧化锆分析仪AZ25/.1.1.2.1.1.5.1.1.1.1.0.0.0.0.E./STD

ABB 氧化锆分析仪AZ25/.1.1.2.1.1.5.3.1.2.0.0.0.0.E.Z.J/STD

ABB 氧化锆分析仪AZ20/112112225111100C/STD

ABB 氧化锆分析仪AZ20/1.2.2.2.1.2.2.3.3.7.1.1.2.E

ABB 氧化锆分析仪AZ20/222122337112E

ABB 氧化锆分析仪AZ20/2.2.2.1.2.2.3.3.7.1.1.21.0.0.E/STD

ABB 氧化锆分析仪AZ20/222122337112E/STD

如果您有任何关于产品的相关技术咨询或者需要产品的相关技术资料与文档,请随时爱泽工业,或者访问我们将尽全力解决您的问题。

If you have any question, please feel free to dial  or browse our Thank you.

收藏该商铺

登录 后再收藏

提示

您的留言已提交成功!我们将在第一时间回复您~
二维码 意见反馈

扫一扫访问手机商铺
在线留言